Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 16 de 16
Filter
1.
Braz. oral res. (Online) ; 34: e004, 2020. tab, graf
Article in English | LILACS | ID: biblio-1055523

ABSTRACT

Abstract The aim of this study was to analyze the structural, morphological and mechanical properties of two different lithium disilicate glass-reinforced ceramics for CAD-CAM systems (IPS e.max CAD and Rosetta SM). Five methodologies were used for both ceramics: microstructure (n = 2) was analyzed using x-ray diffraction (XRD); morphological properties (n = 2) were analyzed by scanning electron microscopy (SEM), with and without hydrofluoric etching; porosity (n = 3) was assessed using 3D micro-computed tomography (micro-CT); flexural strength was measured (n =1 0) using the three-point bending test; and bond strength was determined with self-adhesive resin cement (n = 10), using a microshear bond test. After performing all the tests, the data were analyzed using t-Student test and two-way ANOVA. All the tests used a significance level of α = 0.05. High peak positions corresponding to standard lithium metasilicate and lithium disilicate with similar intensities were observed for both ceramics in the XRD analysis. Morphological analysis showed that the crystalline structure of the two ceramics studied showed no statistical difference after acid etching. Additionally, no significant differences were recorded in the number or size of the pores for the ceramics evaluated. Moreover, no differences in flexural strength were found for the ceramic materials tested, or in the bond strength to ceramic substrates for the resin cements. Based on the study results, no significant differences were found between the two CAD-CAM lithium disilicate glass-reinforced ceramics tested, since they presented similar crystalline structures with comparable intensities, and similar total porosity, flexural strength and bond strength.


Subject(s)
Ceramics/chemistry , Computer-Aided Design , Dental Porcelain/chemistry , Glass/chemistry , Reference Values , Surface Properties , X-Ray Diffraction , Materials Testing , Microscopy, Electron, Scanning , Reproducibility of Results , Analysis of Variance , Porosity , Dental Bonding/methods , Resin Cements/chemistry , Shear Strength , Flexural Strength
2.
Braz. j. oral sci ; 16: e17070, jan.-dez. 2017. ilus
Article in English | LILACS, BBO | ID: biblio-883661

ABSTRACT

The aim of this study was to evaluate the presence of filling material in oval root canals after endodontic retreatment performed by different techniques, considering the area (mm2), location and root third using computed microtomography (µ-CT). Methods: Thirty human lower central incisor underwent biomechanical preparation, root filling and filling removal using two techniques (n=15): MN- manual retreatment technique (Gates Glidden burs and stainless steel manual files); and RT- rotary retreatment technique (ProTaper Universal and ProTaper Retreatment Systems). Cross-sectional images of the teeth were made using µ-CT to identify the presence of remaining filling in all root thirds of the canal walls. The remaining material detected in 150 µ-CT sections was identified and its area quantified (mm2) for each root third individually. Results: Data analysis showed no difference in the remaining area of filling material (p=0.8611) for the both techniques. Higher frequency of remaining material was verified in the lingual wall of the root canals. Regardless of the retreatment technique, the apical third showed lager areas of remaining filling material. More areas of remaining material were detected in the cervical third of the RT group, whereas for the MN group, most areas were observed in the middle and apical thirds. Conclusion: According to our results, no significant differences were verified between the efficiency of the rotary and manual techniques for removing filling material due to the interferences caused by the root canal anatomy (AU)


Subject(s)
Humans , Male , Female , Retreatment , Root Canal Preparation , X-Ray Microtomography
3.
Braz. dent. j ; 28(5): 624-631, Sept.-Oct. 2017. tab, graf
Article in English | LILACS | ID: biblio-888690

ABSTRACT

Abstract The aim of this study was to evaluate the degree of conversion, color stability, chemical composition, and bond strength of a light-cured resin cement contaminated with three different hemostatic solutions. Specimens were prepared for the control (uncontaminated resin cement) and experimental groups (resin cement contaminated with one of the hemostatic solutions) according to the tests. For degree of conversion, DC (n = 5) and color analyses (n = 10), specimens (3 mm in diameter and 2 mm thick) were evaluated by Fourier transform infrared spectroscopy (FTIR) and CIELAB spectrophotometry (L*, a*, b*), respectively. For elemental chemical analysis (n = 1), specimens (2 mm thick and 6 mm in diameter) were evaluated by x-ray energy-dispersive spectroscopy (EDS). The bond strengths of the groups were assessed by the microshear test (n = 20) in a leucite-reinforced glass ceramic substrate, followed by failure mode analysis by scanning electron microscopy (SEM). The mean values, except for the elemental chemical evaluation and failure mode, were evaluated by ANOVA and Tukey's HSD test. The color stability was influenced by storage time (p<0.001) and interaction between contamination and storage time (p<0.001). Hemostop and Viscostat Clear contamination did not affect the DC, however Viscostat increased the DC. Bond strength of the resin cement to ceramic was negatively affected by the contaminants (p<0.001). Contamination by hemostatic agents affected the bond strength, degree of conversion, and color stability of the light-cured resin cement tested.


Resumo O objetivo desse estudo foi avaliar o grau de conversão, estabilidade de cor, composição química e resistência de união de um cimento resinoso fotoativado contaminado com três soluções hemostáticas diferentes. Foram preparadas amostras para o grupo controle (cimento não contaminado) e grupos experimentais (cimento contaminado com uma das soluções hemostáticas) de acordo com os testes. Para o grau de conversão e análise de cor (n=10), as amostras (3 mm de diâmetro e 2 mm de espessura) foram avaliadas por espectroscopia de infravermelho com transformação de Fourier (FTIR) e espectrofotometria CIELAB (L*, A*, B*), respectivamente. Para a análise química elementar (n=1), os espécimes (2 mm de espessura e 6 mm de diâmetro) foram avaliados por espectroscopia de energia dispersiva de raios-x (EDS). As resistências de união dos grupos foram avaliadas pelo ensaio de microcisalhamento (n=20) em um substrato cerâmico de vidro reforçado com leucita, seguida da análise de modo de falha por microscopia eletrônica de varredura (MEV). Os valores médios, com exceção da avaliação química e do modo de falha, foram avaliados por ANOVA e pelo teste de Tukey. A estabilidade de cor foi influenciada pelo tempo de armazenagem (p<0,001) e interação entre a contaminação e o tempo (p<0,001). A contaminação pelo Hemostop e Viscostat Clear não influenciaram no GC, porém a contaminação com Viscostat aumentou o GC. A resistência de união do cimento a cerâmica foi negativamente afetada pelos contaminantes (p<0,001). A contaminação por agentes hemostáticos afetou a resistência de união, o grau de conversão e a estabilidade de cor do cimento resinoso fotoativado testado.


Subject(s)
Hemostatics , Resin Cements/chemistry , Color , Microscopy, Electron, Scanning , Solutions , Spectrum Analysis , Surface Properties
4.
Braz. dent. j ; 28(1): 16-23, Jan.-Feb. 2017. tab, graf
Article in English | LILACS | ID: biblio-839124

ABSTRACT

Abstract The aim of this study was to evaluate the μTBS in different dentin substrates and water-storage periods. Twenty-four dentin blocks obtained from sound third molars were randomly divided into 3 groups: Sound dentin (Sd), Caries-affected dentin (Ca) and Caries-infected dentin (Ci). Dentin blocks from Ca and Ci groups were subjected to artificial caries development (S. mutans biofilm). The softest carious tissue was removed using spherical drills under visual inspection with Caries Detector solution (Ca group). It was considered as Ci (softer and deeply red stained dentin) and Ca (harder and slightly red stained dentin). The Adper Single Bond 2 adhesive system was applied and Z350 composite blocks were built in all groups. Teeth were stored in deionized water for 24 h at 37 ºC and sectioned into beams (1.0 mm2 section area). The beams from each tooth were randomly divided into three storages periods: 24 h, 6 months or 1 year. Specimens were submitted to µTBS using EZ test machine at a crosshead speed of 1.0 mm/min. Failure mode was examined by SEM. Data from µTBS were submitted to split plot two-way ANOVA and Tukey’s HSD tests (a=0.05). The µTBS (MPa) of Sd (41.2) was significantly higher than Ca (32.4) and Ci (27.2), regardless of storage. Ca and Ci after 6 months and 1 year, presented similar µTBS. Mixed and adhesive failures predominated in all groups. The highest µTBS values (48.1±9.1) were found for Sd at 24 h storage. Storage of specimens decreased the µTBS values for all conditions.


Resumo O objetivo neste estudo foi avaliar a resistência de união à microtração (RUµT) de um sistema adesivo convencional (Adper Single Bond 2 - SB) em diferentes substratos dentinários e períodos de armazenagem. Vinte e quatro blocos de dentina foram obtidos de terceiros molares hígidos e separados aleatoriamente em 3 grupos (n=8): dentina sadia (Ds), dentina afetada (Da) e dentina infectada (Di). A Da e a Di foram submetidas ao desenvolvimento biológico artificial de cárie (S. mutans). O tecido cariado amolecido foi removido usando broca esférica sob inspeção visual com a solução Caries Detector (grupo Da). Considerou-se como Di a dentina amolecida e fortemente pigmentada de vermelho e como Da, a dentina hígida e levemente pigmentada de vermelho. O sistema adesivo SB foi aplicado de acordo com as recomendações do fabricante e blocos da resina composta Z350 foram construídos (6 mm de altura). O conjunto (dente/bloco de resina) foi armazenado em água deionizada por 24 horas a 37 °C. Estes foram seccionados em palitos (1,0 mm2 de área), que foram separados aleatoriamente em 3 períodos de armazenagem: 24 horas, 6 meses e 1 ano. Os palitos foram submetidos ao ensaio de resistência de união à microtração na máquina EZ teste a uma velocidade de 1,0 mm/min. Dados de RUµT foram submetidos à Análise de Variância 2 fatores em esquema de parcela subdividida e ao teste de Tukey (a=0,05). Os valores de resistência (MPa) da Ds (41,2) foram significativamente maiores do que os da Da (32,4) e Di (27,2), independente do tempo de armazenagem. Di e Da, 6 meses e 1ano, apresentaram valores similares de resistência de união. As falhas adesivas e mistas foram predominantes para todos os grupos. Em conclusão, os maiores valores de RUµT (48,1±9,1) foram verificados para a Ds e 24 h de armazenagem. A armazenagem diminuiu os valores de RUµT para todas as condições.


Subject(s)
Dentin-Bonding Agents , Dental Caries , Dentin , Tensile Strength , In Vitro Techniques , Microscopy, Electron, Scanning , Healthcare Failure Mode and Effect Analysis , Molar, Third
5.
J. appl. oral sci ; 25(1): 61-68, Jan.-Feb. 2017. tab, graf
Article in English | LILACS, BBO | ID: biblio-841162

ABSTRACT

Abstract Resin cements have led to great advances in dental ceramic restoration techniques because of their ability to bond to both dental structures and restorative materials. Objective The aim of this study was to assess the performance of resin cements when different curing modes are used, by evaluating the degree of conversion and bond strength to a ceramic substrate. Material and Methods Three resin cements were evaluated, two dual-cured (Variolink II and RelyX ARC) and one light-cured (Variolink Veneer). The dual-cured resin cements were tested by using the dual activation mode (base and catalyst) and light-activation mode (base paste only). For degree of conversion (DC) (n=5), a 1.0 mm thick feldspathic ceramic disc was placed over the resin cement specimens and the set was light activated with a QTH unit. After 24 h storage, the DC was measured with Fourier transform infrared spectroscopy (FTIR). For microshear bond strength testing, five feldspathic ceramic discs were submitted to surface treatment, and three cylindrical resin cement specimens were bonded to each ceramic surface according to the experimental groups. After 24 h, microshear bond testing was performed at 0.5 mm/min crosshead speed until the failure. Data were submitted to one-way ANOVA followed by Tukey test (p<0.05). Scanning electron microscopy (SEM) was used for classifying the failure modes. Results Higher DC and bond strength values were shown by the resin cements cured by using the dual activation mode. The Variolink II group presented higher DC and bond strength values when using light-activation only when compared with the Variolink Veneer group. Conclusion The base paste of dual-cured resin cements in light-activation mode can be used for bonding translucent ceramic restorations of up to or less than 1.0 mm thick.


Subject(s)
Polyethylene Glycols/chemistry , Polymethacrylic Acids/chemistry , Ceramics/chemistry , Bisphenol A-Glycidyl Methacrylate/chemistry , Potassium Compounds/chemistry , Resin Cements/chemistry , Light-Curing of Dental Adhesives/methods , Aluminum Silicates/chemistry , Reference Values , Surface Properties , Time Factors , Materials Testing , Microscopy, Electron, Scanning , Reproducibility of Results , Analysis of Variance , Shear Strength , Curing Lights, Dental , Photochemical Processes , Polymerization
6.
Biosci. j. (Online) ; 32(4): 1110-1117, july/aug. 2016. tab, ilus
Article in English | LILACS | ID: biblio-965678

ABSTRACT

This study aimed to assess the efficiency of manual and rotary techniques for removing root filling material in endodontic treated canals and to evaluate the extrusion of debris via apical foramen. After access preparation, thirty human lower central incisors were instrumented, filled and divided into two groups (n=15): MNmanual retreatment technique; RT- rotary retreatment technique. The teeth were submitted to micro-computed tomographic scanning before and after the retreatment procedure, for quantifying the remaining filling material by relating the initial and final conditions. The analysis was conducted separately in all root thirds. The volume of material extruded through the apical foramen was also quantified. The data were statistically analyzed using t-test and two-way analysis of variance (ANOVA) at 5% of significance. No significant differences were detected between remaining filling material for the techniques evaluated (p=0.74), even considering the apical third only (p>0.75). Significant differences were found for the remaining filling material verified between the cervical third and middle/apical thirds, with lower values being observed at the cervical third for both groups (p<0.05). Apical extrusion of filling material was verified in seven specimens (2 from MN group and 5 from RT group). Both techniques showed similar performance for removing filling material from the root canal, considering the whole tooth or the root thirds independently. The apical extrusion of filling material observed was not sufficient to indicate which technique has increased tendency to induce more events during retreatments.


Este estudo objetivou avaliar a eficiência das técnicas manual e rotatória na remoção de material obturador de dentes tratados endodonticamente, além de verificar a extrusão de resíduos via forame apical. Após acesso endodôntico, trinta incisivos centrais inferiores humanos foram instrumentados, obturados e divididos em dois grupos (n=15): MN- técnica de retratamento manual; RT- técnica de retratamento rotatória. Os dentes foram submetidos à escaneamento micro-tomográfico previamente e após os procedimentos de retratamento para quantificação do remanescente de material obturador relacionando as condições inicial e final. Esta análise foi conduzida separadamente em todos os terços radiculares. O volume de material extruído via forame apical também foi quantificado. Os dados foram analisados estatisticamente por meio dos Testes T e de Análise de Variância em dois níveis com significância em 5%. Diferenças significantes não foram detectadas entre a quantidade de material remanescente para as duas técnicas avaliadas (p=0,74), mesmo considerando o terço apical separadamente (p>0.75). Diferenças significantes foram encontradas na quantidade de material remanescente verificado entre os terços cervical e médio/apical, com menores valores detectados no terço cervical para ambos os grupos (p<0.05). Extrusão apical de material obturador foi identificada em sete espécimes (2 do grupo MN e 5 do grupo RT). As duas técnicas avaliadas apresentaram desempenho similar na remoção do material obturador do canal radicular, considerando o dente como um todo ou os terços radiculares separadamente. A extrusão apical de material obturador verificada não foi suficiente para indicar qual técnica possui maior tendência de promover eventos durante o retratamento.


Subject(s)
Root Canal Obturation , Endodontics , Orthodontic Extrusion , X-Ray Microtomography
7.
Biosci. j. (Online) ; 31(2): 657-662, mar./abr. 2015.
Article in English | LILACS | ID: biblio-964123

ABSTRACT

Congenital tooth agenesis and tooth loss due to dental traumatism are some of the most common causes leading to rehabilitation of young patients with dental implants. The success of treating congenitally missing teeth with implant-supported prosthesis is no more guided only by osseointegration criteria. Nowadays the successful rehabilitation of these cases involves the adequate installation of dental implants with suitable prosthetic contour, color, and emergence profile closer to that found in natural dentition. Several treatment options are available for restoring patients with congenitally missing teeth such as maxillary lateral incisors. Fixed prosthodontics and orthodontics managements are considered acceptable treatment protocols. However, the gold standard rehabilitation of congenitally missing maxillary incisors is performed with implant-based prosthesis since no tooth wear neither extensive tooth movements are necessary. The present paper reports the treatment of a young adult woman with congenitally missing maxillary lateral incisors who underwent orthodontic treatment for improvement of teeth alignment and occlusal balance previous to dental implant surgery. This treatment also allowed appropriate space for the future lateral incisors crowns. Then, Morse-type conical implants were positioned and prosthetic abutments installed. Ceramic laminates were planned on central incisors in order to improve anterior aesthetics. All-ceramic crowns and laminates were made using lithium dissilicate-based ceramic (e-Max Press). The multidisciplinary association of orthodontic, implant and prosthetic techniques resulted in successful functional and aesthetic rehabilitation of the case, which was maintained after 1 year follow up.


Agenesias e perdas dentárias devido a traumatismos estão entre as principais causas de reabilitações de pacientes jovens com implantes dentários. O sucesso do tratamento de agenesias com implantes osseointegrados não se limita mais à osseointegração exclusivamente. Atualmente, o sucesso da reabilitação destes casos envolve a correta instalação de implantes que favoreçam a confecção de uma prótese com cor, forma e perfil de emergência o mais semelhante possível aos dentes naturais. Os cirurgiões-dentistas têm várias opções para tratar casos de agenesias como as de incisivos laterais superiores. Próteses fixas convencionais e movimentação ortodôntica são considerados protocolos de tratamento aceitáveis. Entretanto, agenesias de incisivos laterais superiores são reabilitadas satisfatoriamente com próteses sobre implantes uma vez que extensas movimentações ou desgastes dentários são necessários. O presente caso relata o tratamento de uma paciente jovem com agenesia dos incisivos laterais que havia feito tratamento ortodôntico para correção do posicionamento dentário e equilíbrio dental antes de se submeter à cirurgia para instalação de implantes. O tratamento ortodôntico também favoreceu a obtenção de espaço apropriado para instalação das coroas dos incisivos laterais. Posteriormente, implantes cônicos com plataforma protética tipo cone morse foram instalados e pilares selecionados. Laminados cerâmicos foram planejados para os incisivos centrais com objetivo de se promover um resultado final mais harmônico e estético. As coroas em cerâmica pura e laminados foram confeccionados com cerâmica a base de dissilicato de lítio (e.Max Press). A associação multidisciplinar entre tratamento ortodôntico, implantes e próteses sobre implantes resultou no sucesso funcional e estético da reabilitação do presente caso com acompanhamento clínico de uma ano.


Subject(s)
Dental Implants , Osseointegration , Tooth Loss , Dental Veneers , Esthetics, Dental , Anodontia
8.
Braz. oral res. (Online) ; 29(1): 1-9, 2015. tab, ilus
Article in English | LILACS | ID: lil-777169

ABSTRACT

This study aimed to guide the planning of anticurvature filing using pre-determined anatomical points on teeth to establish directions for proper implementation of the technique. Two hundred digital periapical radiographs of human molar teeth were selected and divided into two groups (n = 100): MX (maxillary) and MD (mandibular) molars. Mesiobuccal roots were considered for the MX group and mesial roots for the MD group. Pre-determined anatomical points required for planning the anticurvature filing on the root canal path were located, and the distances between these points obtained. The anticurvature filing was simulated in two different protocols for each group, and the region of dentin removal and the remaining dentin thickness were measured in the safety and danger zones of the root canals. Statistical analysis was carried out at a significance level of 5%. The distances between the anatomical points and the thickness of remaining dentin showed significant differences when the two groups were compared (p < 0.001). No significant differences were found between the two experimental groups regarding the area of dentin removal at the root region, but differences were detected in comparison with dentin removal at the crown (p < 0.001). In terms of wear produced after simulation of both anticurvature filing protocols, significant differences were verified for all regions, except for the dentin remaining at the danger zone. The radiographic location of anatomical points allows for planning and implementation of controlled and efficient anticurvature filing and can be performed in the same manner for maxillary and mandibular molars.


Subject(s)
Humans , Filing , Molar/anatomy & histology , Molar , Root Canal Preparation/methods , Tooth Root/anatomy & histology , Tooth Root , Analysis of Variance , Anatomic Landmarks , Dentin/anatomy & histology , Dentin , Odontometry/methods , Reference Values , Reproducibility of Results , Statistics, Nonparametric
9.
Braz. oral res. (Online) ; 29(1): 1-6, 2015. tab, ilus
Article in English | LILACS | ID: lil-777259

ABSTRACT

The aim of this study was to evaluate the influence of the flexion angle of files on the decentralization of root canals during instrumentation. Fifteen lower incisors were instrumented with Protaper Universal files and radiographed in two directions (mesiodistal and buccolingual) before and after instrumentation with a #15 K-file in position for evaluating the flexion angle of files. The specimens were also scanned before and after instrumentation using micro-computed tomography to obtain the canal area and the distance from the center position of the file to the canal walls. Sections located 1.0 mm (end of the canal), 3.0 mm (apical third), 9.0 mm (middle third), and 15.0 mm (cervical third) from the apex were verified. After instrumentation, the flexion angles of files decreased by an average of 0.76º in the buccolingual direction and 1.92º in the mesiodistal direction (p < 0.001); the canal area increased by an average of 0.58, 0.37, 0.23 and 0.13 mm2 from the cervical to the end of the root canal (p < 0.001). Non-instrumented areas were observed on the buccal and lingual walls, and effective action of files was determined on the mesial and distal walls. The sections from the end of the canal showed canal deviation toward the lingual wall, whereas the other sections showed deviation toward the buccal wall. The flexion angles of files influence the final shape of the root canal, resulting in file decentralization along the pathway of the canal.


Subject(s)
Humans , Dental Pulp Cavity/anatomy & histology , Root Canal Preparation/instrumentation , Anatomy, Cross-Sectional , Dental Instruments , Dental Pulp Cavity , Incisor/anatomy & histology , Incisor , Odontometry , Reference Values , Statistics, Nonparametric , X-Ray Microtomography
10.
Braz. dent. j ; 25(3): 232-236, 07/2014. tab, graf
Article in English | LILACS | ID: lil-722149

ABSTRACT

The aim of this study was to evaluate the root canal anatomy of mandibular incisors before and after endodontic instrumentation, identifying regions inaccessible to the action of files (Critical instrumentation Area - CA) in a three-dimensional perspective. Thirty human mandibular central incisors were selected, assigned to two groups (n=15) and instrumented using ProTaper Universal rotary files. In the RX group, longitudinal digital radiographic images were obtained in the buccolingual (BL) and mesiodistal (MD) views. In the CT group, cross-sectional micro-computed tomography (µCT) images were obtained at 3, 9 and 15 mm from the apex. The canal area of the specimens was evaluated before and after instrumentation using digital images from each group. Data were analyzed using t-test, one-way ANOVA with subdivided parcels and Tukey's test (α=0.05). The canal area found in the MD radiographs was larger than in the BL radiographs, which was also confirmed in the transversal images (p<0.01). The CA was only detected in the MD radiographs and µCT scans. On the root canal configuration, a continuous reduction in the canal conicity was observed in BL radiographs, while in MD view there was a constriction at the cervical third and subsequent increase at the middle third (p<0.01). The conical shape of the root canal was observed only in the BL view. The canal enlargement in BL radiographs was not indicative of homogeneous instrumentation, since unprepared areas (CA) were also verified on the buccal and lingual walls in different images.


Este estudo avaliou a anatomia do canal radicular de incisivos inferiores, antes e após a instrumentação endodôntica, identificando regiões inacessíveis à ação das limas (Área Crítica de instrumentação - AC), em uma perspectiva tridimensional. Trinta incisivos centrais inferiores humanos foram selecionados, divididos em dois grupos (n=15), e instrumentados usando limas rotatórias ProTaper Universal. No grupo RX, imagens longitudinais foram obtidas em duas incidências, vestíbulo-lingual (VL) e mésio-distal (MD), por meio de radiografias digitais. No grupo CT, imagens transversais foram obtidas por meio de microtomografia computadorizada (μTC), em secções localizadas a 3 mm, 9 mm, e 15 mm do ápice. A área do canal das amostras foi avaliada antes e após a instrumentação usando as imagens digitais de cada grupo. Os dados foram analisados por meio do teste t, ANOVA a um critério com parcela subdividida e ao teste de Tukey (α=0,05). A área de canal encontrada nas radiografias MD foi maior do que nas radiografias VL, o que também foi confirmado nas imagens transversais (p<0,01). A Área Crítica de instrumentação só foi detectada nas radiografias MD e nas seções de μTC. Na configuração de canal, a redução contínua na conicidade do canal foi observada nas radiografias VL, enquanto na incidência MD, houve uma constrição no terço cervical e um subsequente aumento no terço médio (p<0,01). A forma cônica do canal radicular foi observada somente na visão VL. O alargamento do canal verificado nas radiografias VL não foi indicativo de instrumentação homogênea, uma vez que áreas não instrumentadas (AC) foram observadas nas paredes vestibular e lingual em visões distintas.


Subject(s)
Humans , Dental Instruments , Dental Pulp Cavity/anatomy & histology , Root Canal Preparation , Incisor
11.
Biosci. j. (Online) ; 30(3): 914-924, may/june 2014. graf
Article in English | LILACS | ID: biblio-947482

ABSTRACT

The surface treatment of fiber posts influence the bonding between composite resin cements and intraradicular retainers, being relevant to the prognostic of teeth without coronal structure. This study aimed to evaluate the different fiber post surface treatment protocols described on literature. The search strategy included a review of PubMed/MEDLINE database using fiber post associated with adhesion; bonding; surface treatment; as keywords. Papers not comprehending English language; assessment of post surface treatment; or testing of materials and their physicmechanical properties were excluded. Studies about glass and quartz fiber post surface treatment were considered for this literature review. Among the 190 articles included, silane agent was the material most used (60.52%) for the surface treatment of fiber posts, followed by application of alcoholic solutions (38.29%), and primer and/or adhesive systems (36.84%). Sandblasting of post surface was mentioned in (17.89%), but it affected the physical and mechanical properties. Hydrogen peroxide was mentioned only in 5.78% and it was shown to result on adequate exposure of the glass fibers without damaging them. It was concluded that a consensus for fiber post surface treatment still not exist in the current literature. Among the protocols described, the one using hydrogen peroxide followed by application of silane seems the most promising, since it allows increased bond strengths without fiber damage.


O processo de tratamento da superfície de pinos pré-fabricados de fibra influencia na união entre cimentos resinosos e esses retentores intra-radiculares, sendo relevante para o prognóstico do tratamento restaurador de dentes sem remanescente coronário. Este estudo objetivou avaliar diferentes protocolos de tratamentos de superfície para pinos de fibra descritos na literatura. Como metodologia, realizou levantamento bibliográfico na plataforma PubMed/MEDLINE, com a palavras-chave fiber post associada à adhesion; bonding; surface treatment. Excluíram-se artigos não redigidos em inglês; que não trataram a superfície do pino; e testes de propriedades físicas-mecânicas. Estudos que trataram a superfície de pinos de fibra de quartzo ou vidro foram incluídos. Dentre os 190 artigos incluídos nesta revisão, o agente silano foi o material mais utilizado (60.52%) para tratamento de superfície de pinos de fibra, seguido pela aplicação de álcool (38.29%), e sistema adesivo (36.84%). O jateamento do pino foi mencionado em 17.89%, mas esta técnica resultou em alteração das propriedades físicas e mecânicas. O peróxido de hidrogênio foi mencionado em 5.78% dos manuscritos, entretanto este tratamento permite a adequada exposição das fibras sem danificá-las. Concluiu-se que não consta na literatura protocolo padrão do tratamento da superfície de pinos de fibra. Dentre os protocolos descritos, o protocolo utilizando peróxido de hidrogênio seguido da aplicação do silano aparece como o mais promissor, pois permite resistência de união aumentada sem promover danos as fibras.


Subject(s)
Post and Core Technique , Dental Pins , Hydrogen Peroxide , Dental Care
12.
Full dent. sci ; 5(17): 163-170, jan. 2014. ilus
Article in Portuguese | LILACS, BBO | ID: lil-706310

ABSTRACT

A presença de diastema entre os dentes anteriores pode gerar desarmonia do sorriso e comprometer a estética do paciente. Com a evolução dos materiais e das técnicas restauradoras, o fechamento de diastema empregando resinas compostas tornou-se alternativa viável para resolução da maioria dos casos clínicos. Este tratamento permite restabelecer a função, possibilitando os contatos interproximais, bem como restabelecimento da estética, proporcionando um sorriso mais harmônico e agradável. Este artigo tem como objetivo relatar um caso clínico de correção de diastemas nos dentes anteriores superiores, utilizando resina composta nanoparticulada pela técnica direta para restabelecimento funcional e estético. O caso foi acompanhado por quatro anos, sendo realizados alguns reparos ao longo desse tempo, demonstrando que o fechamento de diastema com resina composta ‚ uma técnica viável e confiável, além de apresentar boa longevidade


The presence of anterior diastema can result on smile disharmony and compromise the patient’s aesthetic. The evolution of dental materials and techniques has made the use of composite resin for diastema closure a viable option treatment for most clinical cases. It restores function allowing the interproximal contacts, as well as harmony, reestablishing of the smile’s aesthetic. This clinical report aims at demonstrating the clinical correction of an anterior diastema restoring the functional anatomy and especially aesthetic through nanofilled composite resin restorations. The case was followed for 4-years and some repairs were carried out over this time, demonstrating the reliability and viability of the technique, with good longevity of the treatment


Subject(s)
Humans , Male , Young Adult , Diastema , Dental Veneers/adverse effects , Patient Satisfaction , Denture Design/methods , Composite Resins/pharmacokinetics , Smiling/psychology
13.
Braz. dent. j ; 24(4): 340-343, July-Aug/2013. tab, graf
Article in English | LILACS | ID: lil-689832

ABSTRACT

The cure time of endodontic sealers may influence the bond strength of fiber posts to root dentin. Forty teeth were selected and endodontically filled using calcium hydroxide cement and then divided into 2 groups according to the time elapsed between endodontic filling and post luting (n = 20): Immediately - glass fiber post luting immediately after endodontic filling; and Delayed - post luting performed 7 days after endodontic filling. The roots were also subdivided according to resin cement used for post luting (RelyX ARC and RelyX Unicem). The specimens were stored at 37°C for 24 h and sectioned in six 1-mm-thick slices from cervical, middle and apical thirds. The slice specimens were submitted to a push-out test at a crosshead speed of 0.5 mm/min, and the bond strength values obtained (MPa) were submitted to two-way ANOVA in a split-plot arrangement and Tukey's test (α=0.05). For both RelyX ARC and Unicem, the bond strength was significantly higher when the posts were cemented 7 days after the endodontic treatment. RelyX Unicem showed significantly higher bond strength values than RelyX ARC for both cementation periods. It was concluded that post luting should be made after the complete setting of the root canal sealer. Self-adhesive resin cement should be preferred for fiber post luting.


O tempo de presa de cimentos endodônticos pode afetar a resistência de união de pinos de fibra de vidro à dentina radicular. Quarenta dentes foram selecionados e tratados endodonticamente com cimento à base de hidróxido de cálcio. Em seguida, os mesmos foram divididos em dois grupos de acordo com o tempo decorrido entre o tratamento endodôntico e a cimentação definitiva (n=20): Imediato - pinos de fibra de vidro cimentados após o tratamento endodôntico; e Mediato - cimentação do pino realizada 7 dias após o tratamento endodôntico. As raízes foram subdivididas de acordo com o cimento resinoso (RelyX ARC e RelyX Unicem). As amostras foram armazenadas a 37 °C durante 24 h e seccionadas em seis fatias de 1 mm de espessura relacionadas com terços cervical, médio e apical. Os espécimes foram submetidos a teste de push-out a uma velocidade de 0,5 mm/min e os valores de resistência de união obtidos (MPa) foram submetidos à análise de variância em esquema de parcelas subdivididas e teste de Tukey (α=0,05). Para os cimentos RelyX ARC e Unicem, a resistência de união foi maior quando os pinos foram cimentados 7 dias após o tratamento endodôntico. RelyX Unicem apresentou valores de resistência de união superiores ao RelyX ARC para os períodos de cimentação. Concluiu-se que a cimentação do pino de fibra de vidro deve ser feita após o completo tempo de presa do cimento endodôntico. Cimentos resinosos auto-adesivos devem ser preferidos para cimentação de pinos de fibra.


Subject(s)
Humans , Dental Bonding , Dentin/chemistry , Tooth Root/chemistry , Root Canal Filling Materials , Time Factors
14.
Braz. oral res ; 26(4): 378-383, July-Aug. 2012. ilus, tab
Article in English | LILACS | ID: lil-640712

ABSTRACT

The core finishing of cast posts-and-cores after luting is routine in dental practice. However, the effects of the vibrations produced by the rotary cutting instruments over the luting cements are not well-documented. This study evaluated the influence of the time intervals that elapsed between the cementation and the core-finishing procedures on the tensile strength of cast posts-and-cores luted with zinc phosphate cement. Forty-eight bovine incisor roots were selected, endodontically treated, and divided into four groups (n = 12): GA, control (without finishing); GB, GC, and GD, subjected to finishing at 20 minutes, 60 minutes, and 24 hours after cementation, respectively. Root canals were molded, and the resin patterns were cast in copper-aluminum alloy. Cast posts-and-cores were luted with zinc phosphate cement, and the core-finishing procedures were applied according to the groups. The tensile tests were performed at a crosshead speed of 0.5 mm/min for all groups, 24 hours after the core-finishing procedures. The data were subjected to one-way analysis of variance (ANOVA) and Tukey's test (α = 0.05). No significant differences were observed in the tensile strengths between the control and experimental groups, regardless of the time interval that elapsed between the luting and finishing steps. Within the limitations of the present study, it was demonstrated that the core-finishing procedures and time intervals that elapsed after luting did not appear to affect the retention of cast posts-and-cores when zinc phosphate cement was used.


Subject(s)
Animals , Cattle , Dental Polishing/instrumentation , Post and Core Technique , Zinc Phosphate Cement/chemistry , Confidence Intervals , Cementation/methods , Dental Instruments , Dental Prosthesis Retention , Dental Polishing/methods , Materials Testing , Surface Properties , Tensile Strength , Time Factors
15.
Braz. dent. j ; 23(6): 686-691, 2012. ilus, tab
Article in English | LILACS | ID: lil-662427

ABSTRACT

The aim of this study was to assess the effect of different plasma arc welding parameters on the flexural strength of titanium alloy beams (Ti-6Al-4V). Forty Ti-6Al-4V and 10 NiCr alloy beam specimens (40 mm long and 3.18 mm diameter) were prepared and divided into 5 groups (n=10). The titanium alloy beams for the control group were not sectioned or subjected to welding. Groups PL10, PL12, and PL14 contained titanium beams sectioned and welded at current 3 A for 10, 12 or 14 ms, respectively. Group NCB consisted of NiCr alloy beams welded using conventional torch brazing. After, the beams were subjected to a three-point bending test and the values obtained were analyzed to assess the flexural strength (MPa). Statistical analysis was carried out by one-way ANOVA and Tukey's HSD test at 0.05 confidence level. Significant difference was verified among the evaluated groups (p<0.001), with higher flexural strength for the control group (p<0.05). No significant differences was observed among the plasma welded groups (p>0.05). The NCB group showed the lowest flexural strength, although it was statistically similar to the PL 14 group (p>0.05). The weld depth penetration was not significantly different among the plasma welded groups (p=0.05). Three representative specimens were randomly selected to be evaluated under scanning electron microcopy. The composition of the welded regions was analyzed by energy dispersive X-ray spectroscopy. This study provides an initial set of parameters supporting the use of plasma welding during fabrication of titanium alloy dental frameworks.


O objetivo deste estudo foi avaliar o efeito de diferentes parâmetros de solda a plasma verificando a resistência flexural de barras de liga de titânio (Ti-6Al-4V). Quarenta espécimes de Ti-6AL-4V e dez espécimes de liga de NiCr foram preparados (40 mm de altura e 3,18 mm de diâmetro) e divididos em 5 grupos (n=10). As barras de liga titânio do grupo controle não foram seccionadas e nem submetidas a processo de soldagem. Os grupos PL10, PL12 e PL14, continham barras de titânio seccionadas e soldadas com uma corrente de 3 A por períodos de 10,12 e 14 ms, respectivamente. O grupo NCB consistiu de barras de liga de NiCr soldadas pelo método de brasagem convencional. Em seguida as barras foram submetidas ao teste de flexão de três pontos e os valores obtidos foram transformados em resistência flexural (MPa). Análise estatística foi realizada usando ANOVA de fator único e o teste Tukey com o nível de significância de 0,05. Diferença estatística foi verificada entre os grupos avaliados (p<0,001), com os maiores valores pra o grupo controle. Não foram encontradas diferenças entre os grupos de solda plasma (p>0,05). O grupo NCB apresentou os menores valores de resistência flexural embora tenha sido estatisticamente semelhante ao grupo PL14. Não houve diferença significante na profundidade de penetração entre os grupos de solda plasma (p=0,05). Três espécimes representativos foram aleatoriamente selecionados para serem avaliados por meio de microscopia eletrônica de varredura. A composição das regiões soldadas foi verificada por meio de espectroscopia por energia dispersiva. Este estudo fornece informações iniciais de parâmetros para permitir a utilização de soldagem plasma durante a fabricação de estruturas em liga de titânio.


Subject(s)
Humans , Dental Alloys/chemistry , Dental Soldering/methods , Plasma Gases/chemistry , Titanium/chemistry , Argon/chemistry , Chromium Alloys/chemistry , Dental Soldering/instrumentation , Materials Testing , Microscopy, Electron, Scanning , Pliability , Spectrometry, X-Ray Emission , Stress, Mechanical , Surface Properties , Welding/instrumentation , Welding/methods
16.
J. appl. oral sci ; 17(2): 140-144, Mar.-Apr. 2009. ilus
Article in English | LILACS | ID: lil-503993

ABSTRACT

The esthetic and functional rehabilitation of patients with multiple missing teeth can be performed with several techniques and materials. Ceramic restorations provide reliable masticatory function and good esthetics. However, fracture can occur in some cases due to their brittle behavior. In some cases, the replacement of an extensive prosthesis is a problem due to the high treatment cost. In this paper, two cases are presented, in which fractures occurred in extensive metal-ceramic fixed partial dentures, and their replacement was not possible. Ceramic repair was chosen and the sequences of treatment with and without presence of the ceramic fragment are also discussed. The cases illustrate that, in some situations, fractured metal-ceramic partial dentures can be successfully repaired when prosthetic replacement is not a choice. Prosthodontists must use alternatives that allow a reliable repair to extensive metal-ceramic fixed partial dentures. Surface preparation of the ceramic with hydrofluoric acid in conjunction with a silane coupling agent is essential for a predictable bonding of composite resin. The repair performed with composite resin is an esthetic and functional alternative when extensive fixed partial dentures cannot be replaced.


Subject(s)
Female , Humans , Middle Aged , Dental Porcelain , Denture, Partial, Fixed , Denture Repair/methods , Acid Etching, Dental , Composite Resins , Dental Bonding/methods , Metal Ceramic Alloys , Resin Cements , Silanes
SELECTION OF CITATIONS
SEARCH DETAIL